9
Griddle
These griddles are fitted with a pilot as a standard
option and Flame Failure Protection, which is
incorporated by way of a thermo-electric system for
each main burner. Flame Failure Protection will shut
off the gas supply to that burner in the event that
the pilot for that burner goes out, so that un-burnt
gas is not expelled. This is an important safety
feature which is slowly becoming law throughout
the world.
Lighting the Griddle
a. Depress the gas control knob and rotate anti-
clockwise to the ‘PILOT’ position.
b. With the gas control knob depressed, press the
piezo ignition button to ignite the pilot burner.
Repeat Items 1 to 2 until the pilot is lit.
c. Release the gas control knob approximately 10
to 20 seconds after lighting the pilot.
d. The pilot should now remain alight - if not, repeat
Steps (a to (c above.
e. ‘Full Flame’ can now be achieved by depressing
and rotating the gas control knob anti-clockwise
to the first stop.
f. Low flame can be achieved by depressing the
gas control knob and rotating fully anti-
clockwise to the ‘Low Flame’ position.
g. When the main burner is not required, depress
and turn the gas control knob clockwise back to
the ‘PILOT’ ‘OFF’ position.
h. To turn 'Off' the main burner, depress and turn
the gas control knob clockwise back to the
‘OFF’ position. The pilot will extinguish.
Part 4 Operation
Open Burners
NOTE:
Only cooking pans from size Ø 150 mm to Ø 420
mm are suitable fo use on these open burners.
Lighting the Open Burners
(Flame Failure Protection is incorporated as
standard for the UK Market and optional for Non -UK
Markets, for each burner by way of a thermo-
electric system which will shut off the gas supply to
that burner in the event that the burner goes out, so
that un-burnt gas is not expelled).
a. Select the burner required, depress and turn the
corresponding gas control knob anti-clockwise
to the ‘HIGH’ position.
b. With the gas control knob depressed, manually
light the burner.
c. Release the gas control knob after
approximately 10-20 seconds after lighting the
burner.
d. The burner should stay alight - if not, repeat
Steps (a to (c above.
e. To achieve simmer control, depress the gas
control knob and rotate between the ‘HIGH’
and ‘LOW’ positions to achieve the temperature
required.
Turning 'OFF' the Open Burners
a. When the main burner is not required, depress
and turn the gas control knob clockwise back to
the ‘OFF’ position. The 'MAIN' burner will
extinguish.
C
AUTION
:
The griddle plate temperature reaches over
300°C in hottest points during normal
operation at 'Full Flame' setting.
Should any abnormal operation like;
- ignition problems,
- abnormal burner flame,
- burner control problems,
- partial or full loss of burner flame in normal
operation,
be noticed, the appliance requires IMMEDIATE
service by a qualified service person and shall not
be used until such service is carried out.
IMPORTANT