Part 6 Gas Conversion
Gas Specifications
- Non-UK Only
- UK Only
Appliance Classification
Category: II
2H3P.
Flue Type: A
1.
NOTE:
* The burner operating pressure is to be measured at the manifold test point with two burners
operating at the ‘High’ setting. The operating pressure is ex-factory set through the appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion. (Refer to the
‘Gas Conversion’ section for details).
Natural. Gas LP Gas (Propane)
Burner Injector
Ø 2.10 mm Ø 1.30 mm
Low Fire Setting
¾ turn open
c.c.w.
¼ turn open
c.c.w.
Burner Aeration Setting
16 mm open. 16 mm open.
Griddle
Burner Injector
Ø 2.00 mm Ø 1.25 mm
Pilot Injector
0.35 0.23
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure
1.0 kPa (*) 2.6 kPa (*)
Gas Regulator Cap Screw
Open Burner
Burner Aeration Setting
Fully open. Fully open.
Low Fire Setting
5
/
8
turn open
c.c.w.
3
/
8
turn open
c.c.w.
Natural. Gas
(G20)
Propane
(G31)
Burner Injector
Ø 1.90 mm Ø 1.20 mm
Low Fire Setting
¾ turn open
c.c.w.
¼ turn open
c.c.w.
Burner Aeration Setting
16 mm open. 16 mm open.
Griddle
Burner Injector
Ø 2.00 mm Ø 1.25 mm
Pilot Injector
0.35 0.23
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure
10 mbar (*) 28 mbar (*)
Gas Regulator Cap Screw
Open Burner
Burner Aeration Setting
Fully open. Fully open.
Low Fire Setting
5
/
8
turn open
c.c.w.
3
/
8
turn open
c.c.w.