NOTE: (*)
* - The burner operating pressure is to be measured
at the manifold test point with two burners
operating at full setting. The operating pressure
is ex-factory set, through the appliance regulator
and is not to be adjusted, apart from when
carrying out gas conversion, if required. (Refer
to the ‘Gas Conversion Instruction Sheet’ for this
appliance for further details).
Gas Connection
Gas supply connection point is located at the rear
of the appliance, approximately 130 mm from the
right hand side and 630 mm from the floor. It is
reached from beneath the appliance. (Refer to the
‘Dimensions’ section).
Connection is ¾" BSP male thread (for all models).
Part 2 Specifications
Model Covered in this Specification -
C6D [1] Cooktop 4 Open Burners.
C6C [1] Cooktop 2 Burners + 300mm Griddle.
C6B Cooktop 600mm Griddle.
C9D [1] Cooktop 6 Open Burners.
C9C [1] Cooktop 4 Burners + 300mm Griddle.
C9B [1] Cooktop 2 Burners + 600mm Griddle.
C9A Cooktop 900mm Griddle.
[1] - Open Burner Options:-
F - With Flame Failure Protection.
- Standard Burners.
General
A heavy duty, high efficiency Cooktop for modular
kitchens. It has a high option Cooktop / Griddle
arrangement and is available on adjustable front
feet and robust rear rollers. Five griddle options with
2 models of base unit are available. Fitted with
'Individual Flame Failure' Option (F) for each open
burner. (Standard for UK - Optional for Non UK)
Griddles are fitted with pilot, flame failure and piezo
ignition as standard. These cooktops have an easy
clean stainless steel external finish.
Gas Supply Requirements
- Non - UK Only:
- UK Only:
Natural Gas
(G20)
Propane
(G31)
Open Burner
(each)
Griddle
(each 300mm
section)
Open Burner
(each)
Griddle
(each 300mm
section)
Heat Input (net)
Nominal
5.0 kW 5.0 kW 4.6 kW 5.0 kW
Reduced
1.7 kW 1.5 kW 1.5 kW 2.2 kW
Gas Rate (net)
Nominal
0.53 m
3
/hr 0.53 m
3
/hr 0.36 kg/hr 0.39 kg/hr
Reduced
0.18 m
3
/hr 0.16 m
3
/hr 0.12 kg/hr 0.17 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure
10 mbar (*)
Gas Connection
¾” BSP Male
28 mbar (*)
Natural Gas LP Gas (Propane)
Open Burner
(each)
Griddle
(each 300mm
section)
Open Burner
(each)
Griddle
(each 300mm
section)
Input Rate (N.H.G.C.)
22 MJ/hr
(20,000 Btu/hr)
20 MJ/hr
(18,956 Btu/hr)
22 MJ/hr
(20,000 Btu/hr)
20 MJ/hr
(18,956 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” -13.5” w.c.)
2.75 - 4.50 kPa
(11” -18.0”w.c.)
Burner Operating Pressure
1.0 kPa (*)
(4.0” w.c.)
2.6 kPa (*)
(10.0” w.c.)
Gas Connection
¾” BSP Male